Thingsee AIR

 

 

Thingsee AIR is a state of the art, battery powered wireless IoT sensor for your indoor air quality monitoring. Together with Co², TVOC, temperature, barometric pressure, humidity sensors and ambient light sensor, it’s a perfect device to provide an extensive overlook to both present air quality data and the data history.

Thingsee AIR is part of Haltian Thingsee IoT solution and product family.

Default measurement and reporting

Event based reporting

  • Measures every 5 minutes:
    • CO₂
    • TVOC
    • Temperature
    • Humidity
    • Barometric pressure
    • Ambient light
  • Reports immediately when measured value has changed more than the set threshold value from previous reported measurement:
    • CO₂ default threshold value 10 ppm
    • TVOC default threshold value 30 ppb
    • Temperature when absolute change 0,5 °C
    • Humidity when absolute change 2 %
    • Barometric pressure when absolute change 20 hPa
    • Ambient light when absolute change 10000 nW/cm2
  • Time based reporting:
    • Reports all measurement values every 1 hour

Other default settings

  • Battery reporting interval 6 hours
  • Sensor is in routing mode

Changing the default settings

The following parameters are configurable remotely over Thingsee Operations Cloud

  • Measurement interval
  • Reporting interval
  • Event based reporting thresholds
  • Mesh network node role configuration
    • Routing
    • Non-routing

Device info

Operating temperature +5 °C … +50° C
Operating humidity 0 % … 85 % RH non-condensing
Storage temperature +5 °C … +25 °C
Storage humidity 45% … 85 % RH non-condensing
IP rating grade: IP30
Certifications: CE, FCC, ISED, RoHS and RCM compliant
Battery type: 2 x AA, replaceable
Expected battery life:
• Up to 2 years with 5 minute interval
Radio sensitivity: -95 dBm (BTLE)

Product information

Product name Thingsee AIR
Product description Indoor AIR quality measurement
Vendor name Haltian Oy
Product type Wirepas sensor
Internal Model Code (IMC prefix for TUID)
  • TSAR01
  • XXAR01

Sensor measurement specifications

CO₂
  • Measure CO₂ levels indoors
  • Measurement range 400 – 5000 ppm, extended range up to 10 000 ppm
  • Accuracy ±3 % (In extended range ±10 %)
  • Automatic baseline calibration takes 8 days, and requires that the CO₂ level drops at least once per day
  • Possibility for manual baseline calibration
  • CO₂ sensor is a nondispersive infrared sensor (NDIR)
TVOC
  • Total volatile organic compounds
  • Resolution is 1 ppb at range 0 ppb-2008 ppb
  • Resolution is 6 ppb at range 2008 ppb – 11110 ppb
  • Resolution is 32 ppb at range 11110 ppb – 60000 ppb
  • Automatic baseline calibration takes 24 hours.
Temperature
  • Measurement range -40 to +85 °C
  • Please note recommended operation temperature +5 ºC to +50 ºC
  • Accuracy is ±0.2°C
Relative humidity
  • Relative humidity can be measured between 0 -100% RH
  • Accuracy is ±2%
Barometric pressure
  • Measurement range 300 – 1200 hPa
  • Absolute accuracy ±1hPa
  • Barometric sensor precision ±0.002hPa
Ambient light
  • Ambient light sensing between 0 – 100k nW/cm2
  • Measurement is not calibrated
  • Use only for indicative purposes

Hardware info

Northbound interfaces
  • nRF52832 (Wirepas)
Battery type 2 x AA (replaceable)

Dimensions

Width 55.95mm
Height 26.88mm
Length 92.95mm
Weight 100 g

Operating conditions

Environment
  • Operating temperature +5°C … +50°C
  • Operating humidity 0% … 85% RH non-condensing
  • Storage temperature 5°C … +25°C
  • Storage humidity 45% … 85% RH non-condensing
  • IP rating IP30

Certifications

CEThingsee AIR CE
FCCDTS GRANT 2AEU3TSAIR
JAB GRANT 2AEU3TSAIR
ISED64983RCB.001 ISED
RCMAustralia ACMA SDoC Thingsee AIR TCO