Thingsee AIR

Product information

Product name Thingsee AIR
Product description Indoor AIR quality measurement
Vendor name Haltian Oy
Product type Wirepas sensor
Internal Model Code (IMC prefix for TUID) TSAR01 XXAR01

Sensor measurement specifications

CO₂
  • Measure CO₂ levels indoors
  • Measurement range 400 ... 5000 ppm
  • Accuracy is ±(30ppm +3% of reading)
  • Automatic baseline calibration takes 8 days, and requires that the CO₂ level drops at least once per day
  • Possibility for manual baseline calibration
  • CO₂ sensor is a nondispersive infrared sensor (NDIR)
TVOC
  • Total volatile organic compounds
  • Measurement range 0 ... 60000 ppb
  • Resolution is 1ppb at range 0ppb-2008ppb
  • Resolution is 6ppb at range 2008ppb – 11110ppb
  • Resolution is 32 ppb at range 11110ppb - 60000ppb
  • Automatic baseline calibration takes 24 hours.
Temperature
  • Measurement range -40 ... 85 °C
  • Accuracy is ±0.2°C
Relative humidity
  • Measurement range 0 ... 100 % RH
  • Accuracy is ±2%
Barometric pressure
  • Measurement range 300 ... 1200 hPa
  • Absolute accuracy ±1hPa
  • Barometric sensor precision ±0.002hPa
Ambient light
  • Measurement range 0 ... 100000 lux
  • Measurement is not calibrated
  • Use only for indicative purposes

Hardware info

Northbound interfaces
  • Wirepas nRF52832 2.4GHz

Environment info

Environment
  • Operating temperature 5°C ... +50°C
  • Operating humidity 0% ... 85% RH non-condensing
  • Storage temperature 5°C ... +25°C
  • Storage humidity 45% ... 85% RH non-condensing
  • IP rating IP30

Certifications

CE Not yet available
FCC Not yet available
ISED Not yet available

Device descriptor for developers

HTTP GET https://support.haltian.com/device/tsar01/device.json

Download device descriptor (JSON)

Firmware versions

Installation instructions