Thingsee ENVIRONMENT RUGGED

Device info

  • Operating temperature: -20°C … +50°C
  • Operating humidity: 0% … 100% RH non-condensing
  • Storage temperature: 0°C … 25°C
  • Storage humidity: 45% … 85% RH non-condensing
  • IP rating grade: IP67
  • Certifications: CE, FCC, ISED and RoHS compliant
  • Battery type: 2 x AAA, fixed
  • Expected battery life:
    • Up to 5 years with 5 minute interval (default)
    • Up to 4 years with 1 minute interval
    • Up to 6 years with 15 minute interval
    • Up to 4 years with Machine Usage Mode
  • Radio sensitivity: -95 dBm (BTLE)

Detection capabilities

Check the locations of actual sensor components for optimal installation

  • Temperature -40 ºC to + 85 ºC. Limited to -20 ºC to +50 ºC due to primary battery specification. Usage prohibited in moisture condensing/freezing environments.
    Accuracy ±0,3 ºC.
  • Accelerometer reports orientation or vibrations count in machine usage monitoring mode from 0 – 8G and 0 – 16G in high movement mode.
  • Ambient light sensing between 0 – 100 k lux. Light level measurement not calibrated. Only for indicative purposes.
  • Magneto-resistive sensor. Detects magnetic field from a magnet or high DC current.

Default measurement and reporting

Event based reporting
Measures every 5 minutes:

  • Temperature when absolute change 0,5
  • Ambient light when absolute change 10000
  • x, y, z-axis gravity
  • Count of changes in magnetic switch

Time based reporting

  • Reports all measurement values every 1 hour

Machine usage mode

  • Measurement frequency: 50Hz
  • Reporting interval: 1 minute – Only reports measurement periods where activity was detected
  • Detected vibration range: 128mG – 8G/16G
  • Battery life up to 4 years

Radio connectivity: Wirepas Mesh

Other default settings

  • Battery reporting interval 6 hours
  • Sensor is in routing mode

Changing the default settings

The following parameters are configurable remotely over Thingsee Operations Cloud

  • Measurement interval
  • Reporting interval
  • Event based reporting thresholds
  • Mesh network node role configuration
    • Routing
    • Non-routing